Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM05623
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/19/2018 | MCASTRO2 | ZONING | REVIEW | Approved | |
| 07/19/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 07/19/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 07/19/2018 | MCASTRO2 | ENGINEERING | REVIEW | Passed | |
| 07/19/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide an automatic faucet for the lavatory, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucet will operate for a minimum time of 10-seconds. Reference: Section 424.10, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. Provide tempered water for the public restroom lavatory using an approved device conforming to ASSE 1070. Reference: Section 607.1.2, IPC 2012. |
| 07/19/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 07/24/2018 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 08/02/2018 | SVALENZ1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 08/16/2018 | SVALENZ1 | BUILDING-COMMERCIAL | REVIEW | Passed |