Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM05106
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/28/2018 | ALEXANDRA HINES | ZONING | REVIEW | Approved | |
06/28/2018 | AHINES2 | ENGINEERING | REVIEW | Passed | |
06/29/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. #1 Refer to mechanical plans for the operation of the exhaust fans and revise electrical plan. #2. Please indicate what is new and existing for power and lighting equipment and devices. Ref: 2012 IBC sec 107.2.1, 2011 NEC . |
06/29/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
06/29/2018 | GPERU1 | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide framing details of all new walls that show anchorage to the floor and roof/ceiling. 2. Drinking fountains are required for persons in wheelchairs and standing use. Specify ADA drinking fountains. 3. Provide and exiting plan for the new office; specify the common path of egress travel and maximum travel distance from the office. |
06/29/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
06/29/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Revise the venting configuration for P4 and P-5 in the partial waste & vent diagram: either show the fixtures as being common vented or provide two individual vents (using air admittance valves). 2. One of the two drinking fountains is to be mounted with maximum a spout height of 36" AFF and the other with a spout height of 38-43" AFF. Reference: Section 602.4, ANSI/ICC A117.1-2009. 3. What is P-7 (detail A/P1.1)? 4. Provide architectural detail showing how to anchor water heater bracket to wall. |
07/03/2018 | SVALENZ1 | FIRE | REVIEW | Needs Review | |
07/03/2018 | SVALENZ1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |