Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM04494
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/12/2018 | ALEXANDRA HINES | ZONING | REVIEW | Approved | |
06/12/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide structural calculations and details to show that the Type I hood is supported from the building structure in accordance with Section 507.6, IMC 2012 (the hood hanging weight plus the weight of personnel working in or on the hood). Reference: Section 302.1, IMC 2012. 2. Provide a work platform for the exhaust fan per Section 306.5.1, IMC 2012. 3. Provide a Type II hood over the hot table. Reference: Section 507.2.2, IMC 2012. 4. Clarify the balancing requirements for the make-up air (i.e. where does the required additional 88 CFM come from?). Note that the supplied shop drawings have a different air flow rate for the make-up air. |
06/12/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
06/12/2018 | KROBLES1 | ENGINEERING | REVIEW | Passed | |
06/12/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet g1.0; Code Review: Please revise the accessibility code to the 2009 ICC/ANSI A117.1. 2. Sheet S1.0; Plan and Details: The City of Tucson requires all lettering (upper and lower case) to be a minimum of 3/32" in height. Please revise. 3. Sheets FS3.0, FS3.1, FS3.2, and FS3.3; Notes: The City of Tucson requires all lettering (upper and lower case) to be a minimum of 3/32" in height. Please revise. 4. General: Please provide written responses to all review comments. |
06/12/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
06/12/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
06/12/2018 | KROBLES1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
08/22/2018 | ARUIZ1 | FIRE | REVIEW | Needs Review |