Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM04426
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/07/2018 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 06/07/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Revise the size of the dryer exhaust vent. Reference: Section 504.6.1, IMC 2012. 2. Provide a permanent label showing the total equivalent length of the installed dryer exhaust vent. Reference: section 504.6.5, IMC 2012. 3. Provide cooling/heating load calculations justifying the AC units being installed. 4. Provide a mechanical COMcheck demonstrating that the new AC units comply with the current energy code. 5. Provide makeup air for the dryer. Reference: Section 504.5, IMC 2012. |
| 06/07/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 06/07/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 06/07/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A1.0; Project Data: Please indicate the occupant load on the drawings for this new unit. 2. Sheet A2.0; Wall Legend: The new wall indicates to see Detail 5/A4.0. Please revise the detail reference. 3. Sheet A4.0; Detail 4: If this is for new door lintels, please indicate on Detail 9 that this lintel is for existing and new steel lintels. 4. General: Please provide written responses to all review comments. |
| 06/07/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide automatic faucets for the lavatories, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucets will operate for a minimum time of 10-seconds. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. Where is the hot water source located? If the source is greater than 50-feet from the loads, revise the design to reduce the effective pipe length or add heat tracing.. Reference: Section 607.2, IPC 2012. 3. Provide pressure-absorbing devices for the water connections to appliances equipped with quick-acting or solenoid valves (e.g. clotheswasher). Reference: Section 604.9, IPC 2012. |
| 06/08/2018 | EHAMBLI1 | ENGINEERING | REVIEW | Passed | |
| 06/08/2018 | EHAMBLI1 | ZONING | REVIEW | Approved | |
| 06/08/2018 | MARTIN BROWN | FIRE | REVIEW | Approved |