Review Details: COMMERCIAL - NEW

Permit Number - T18CM03853
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/28/2018 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
09/28/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Comment not addressed. [Second comment: Re-label the two restrooms to coordinate with the floor plan on sheet A101.] [Initial comment: Section 2902.2, IBC 2012 requires that separate toilet facilities be provided for each sex in occupancies with 15 or more occupants. In addition, Section 2902.3, IBC 2012 requires distribution of fixtures based on 50% for each sex unless otherwise approved by the building official.]
2. Correct and complete the scupper calculations. "X" is not a valid dimension for the scuppers and calling for a 20" downspout is questionable. [Second comment: The submitted calculations are for rectangular scuppers; round scuppers will require different calculations. Note that each scupper serves a distinct portion of the roof and surrounding vertical walls.] [Initial comment: Provide hydraulic scupper size calculations for the round scuppers based on the 100-year hourly rainfall rate for Tucson, 3" per hour and a maximum storm water level based on the structural capacity of the roof. Reference: Sections 1106.1, 1106.4, and 1108.3, IPC 2012 and Sections 1611.1 and 1611.3, IBC 2012.]
10/01/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: T18CM03853
Building Plan Review (3rd Review)
4646 E 22nd Street

TRANSMITTAL DATE: October 1, 2018

DUE DATE: October 8, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. COMMENT: Zoning has reviewed the Building plans for compliance with the approved development package. While the building footprint and the site revisions are consistent with the approved DP as it relates to the zoning review purview (Building footprint, Height, square footage, site conditions etc.) zoning cannot approve the building plans until the PDSD Commercial Plans reviewers have approved the building plans.

2. COMMENT: As of this building plan review the approved DP had not been scanned by PDSD records even though the DP has been approved it has not been issued. In addition there are still outstanding fees on the DP. However zoning was able to do a comparison of the proposed building plans with the approved DP that is still in the plans room.

3. COMMENT: Zoning will review the building plans on the next submittal to assure that any revisions made to the building plans do not affect zoning requirements.

4. COMMENT: The electrical site plan sheets in the building package have not been revised to match the site plan in the approved DP. Revise the electrical site plan sheets before re-submitting the building package.

5. COMMENT: ON building package site plan sheet as100 there is an annotation that states that there is "covered parking equipment". The approved DP does not indicate that there will be covered parking on the site. If there is to be a covered parking structure on the site as noted in the BP site plan, the DP must be revised to show the size, location and height of the structure. If the parking structure is to be provided on this development indicate if it is with this building permit or a separate permit.


If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised building package as noted by the zoning comments.
10/05/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change 1) Engineering can conduct an over the counter review once any outstanding comments from other departments have been addressed.

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
10/05/2018 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change There was no response to the electrical review comments located in the plan submittal or revised electrical as requested per the previous review.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/09/2018 QJONES1 APPROVAL SHELF Completed
10/09/2018 QJONES1 OUT TO CUSTOMER Completed
10/09/2018 QJONES1 REJECT SHELF Completed