Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T18CM03549
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/18/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide a point use water dispenser and show the location on the floor plan. Accessibility is required so show required maneuvering spaces to the dispenser. Show the location on the floor plan and water supply on the plumbing plan. CITY OF TUCSON POLICY. 2. Specify how new partitions are anchored to the floro/roof ceiling; list fasteners and ICC EVAL. REPORT NO. IBC 107.2.1 |
| 05/23/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Initial comment was not addressed. The developed length of the hot water supply piping appears to be greater than fifty feet; provide a method for maintaining the temperature of the hot water supply system. Reference: Section 607.2, IPC 2012. |
| 05/25/2018 | LPEREZ2 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |