Permit Number: T18CM03069
Parcel: 11016221A

Address:
6255 E GRANT RD

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T18CM03069
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2018 STEVE SHIELDS ZONING REVIEW Approved
04/24/2018 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
04/24/2018 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
04/24/2018 BLARSON1 ENGINEERING REVIEW Passed PASSED BY STEVE
04/24/2018 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
04/24/2018 ROBERT SHERRY WATER REVIEW Completed
04/24/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Relocate the gas shutoff valve (detail 14) to a location upstream of the dirt leg. reference Section 408.4, IFGC 2012.
2. Provide separate indirect waste pipes for each compartment of the 4-compartment sink to protect against cross-contamination or fouling. Reference: Sections 801.2 and 802.1.8, IPC 2012.
04/24/2018 MARTIN BROWN FIRE REVIEW Approved
04/24/2018 BLARSON1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
07/19/2018 AVAUGHN1 OUT TO CUSTOMER Completed