Permit Number: T18CM02655
Parcel: 131131110

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T18CM02655
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/11/2018 MCASTRO2 ZONING REVIEW Reqs Change CDRC TRANSMITTAL



FROM: Mark Castro
Lead Planner

PROJECT:
T18CM02655
2509 S Sahuara Ave.
Garage Addition


TRANSMITTAL: 4/11/18


COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

This site is located in the R-1 zone (UDC 4.7.9). Single-family residential is a permitted use in this zone (Table 4.8-2). ). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a).

The applicant has constructed a garage, 15'-5" as measured from the front street lot line.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

Based on a wall height of 9'-9", a perimter yard setback of 6'-5" is required as measured to the north lot line. The applicant constructed the garage with a setback of 6'-0".

A variance is required for the reduced building setback as measured to the front street and north lot lines.
08/09/2018 MCASTRO2 ENGINEERING REVIEW Passed
08/09/2018 MCASTRO2 NPPO REVIEW Passed
08/09/2018 MCASTRO2 BUILDING-RESIDENTIAL REVIEW Needs Review