Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM02394
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/10/2018 | JVINCEN1 | FIRE | REVIEW | Approved | |
04/26/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Verify that the specified sensor faucets for the public lavatories have an automatic time-out so that they will dispense a maximum of 0.25 gallons per metering cycle. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. Verify that all of the vents (i.e. "VBG") rise vertically to at least 6" above the flood rims of the fixtures they protect prior to running horizontally. (Note: see the definition of "horizontal" in Section 202, IPC 2012.) Reference: Section 905.4, IPC 2012. |
04/26/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
04/26/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
05/01/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments, Also provide a written response. #1. Where is the Key or legend for the numbers in the hexagon boxes? Or is this not relevant to this project. Ref: Plan Sheets, E1, E1.1, E1.2. #2. What does "REF1-E4" refer to ? Ref: Plan Sheet RE1.1. #3. Include the new Compressor House transformer, panels 'CHA, CHL, feeders, disconnects, conduit, conductor sizes and types in the Line Diagram. Also include in the load calcs. #4. Per comment #1. ( numbered hexagon boxes ) it is unclear as to the scope of work proposed for the exterior building lighting. If the exterior lighting is being modified or retrofitted, then Outdoor Lighting Code compliance will be required. #5. Please provide a narrative for the proposed electrical work to be performed for this project. Ref; 2012 IBC 107.2.1, 2011 NEC, Tucson/Pima County Outdoor Lighting Code. |
05/30/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | 1. Sheet A2; Rear Elevation 3: At overhead door 7 (near Grid 6), the elevation indicates a dock leveller at the door, while the floor plan on Sheet A1 does not indicate the leveller. Please clarify. 2. Sheet A2; Side Elevation 4: The floor plan on Sheet A1 indicates a door at Grid J, while the elevation doe not indicate a door in that location. Please clarify. 3. General: Please provide written responses to all review comments. |