Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T18CM02367
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/25/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. The condensate drains for the showroom building are not shown on the plumbing drawings. [Initial comment: Show the size, routing, and termination of the condensate drains for the three new heat pumps. Reference: Section 307.2.1, IMC 2012 as amended by the City of Tucson.] 2. Provide the revised energy code analysis (COMcheck). [Initial comment: Revise the energy code analysis for the building envelope, coordinating the building components used in the analysis with those shown on the drawing. Reference: Section C303.1, IECC 2012, as amended by the City of Tucson.] 3. Provide the revised energy code analysis (COMcheck). [Initial comment: Provide NFRC fenestration product ratings for the Solar Heat Gain Coefficient (SHGC) on COMcheck per footnote b of the envelope assembly descriptions or use the appropriate default SHGC from Table C303.1.3 (2), IECC 2012. |
| 05/25/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 05/29/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Previous Comment 1; Sheet T1: The S-1 storage occupant load on this sheet was determined to be 47 total occupants. The new plumbing fixture tabulation indicates 45 male and 2 female occupants in this portion of this building. Although it makes no difference in the number of restrooms, lavatories, or drinking fountains in this building, the IBC Section 2902.1.1 indicates the total occupant load shall be divided in half to get the number of female and male occupants. An exception to this section indicates that if there is statistical data, this 50% requirement can be revised. The City of Tucson requires the licensed design professional to provide a sealed, signed, dated statement that the owner has indicated this occupanct load revision is statistically correct. Please revise the plumbing calculations on Sheet T1 if the owner verification is not provided, or leave this sheet as is if the owner verification is provided. No change for the number of water closets or lavatories will be required for this building. 2. Sheet T1; Building Area: The total Building 1 area indicated on this sheet lists 37,558 GSF. Further down in the Development Data, the allowable SF with increases for frontage and automatic sprinklers is listed as 33,750 SF per floor. Please indicate on this sheet that the total first floor SF is less than that 33,750 SF. 3. Sheet T1; Occupant Load: The total occupant load for this building is not calculated on this sheet. Please determine the total occupant load for Building 1 including the existing showroom, the new first floor addition, the new second floor addition, the existing service area, and the existing carwash. Verify the Plumbing Fixture Tabulation is correct as shown for this permit. 4. General: Please provide written responses to all review comments. |
| 06/07/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comment. Also provide a written response. As per the previous electrical plan review comment #1c,"Could not refer to project # M3-PN124055 for the existing lumen calcs. Provide a permit or activity number if available. Otherwise provide a lighting site plan with the locations and complete inventory of all exterior luminaires". …. The response to that comment was to refer to activity T12CM07876, the lighting calcs for that project show total lumens for at 393,750 shielded lumens and a parcel size of 3.8 acres. This does not correlate with the existing lumens shown on your lumen calcs and parcel size for the proposed new exterior lighting. Please provide a lighting site plan with the locations of all proposed and existing exterior lighting, and up to date lumen calcs, as required per the Outdoor lighting Code sections 102.4, 104.2. Dan.santacruz@tucsonaz.gov |
| 06/13/2018 | MMORENO1 | ZONING | REVIEW | Denied | FROM: Michael Moreno PDSD Zoning Review Section PROJECT: T18CM02367 - Tenement Improvement Building Plan Review (2nd Review) Tucson Subaru 4901 N Oracle Rd. TRANSMITTAL DATE: June 13, 2018 DUE DATE: June 14, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: Zoning has reviewed the building plans for compliance with the approved development package. While the building footprint and the site revisions are consistent with the approved DP as it relates to the zoning review purview (Building footprint, Height, square footage, site conditions etc) zoning cannot approve the building plans until the Commercial Plans reviewers have approved the building plans. 2. COMMENT: The development package sheets provided in the building plan set should either be the approved set or marked as reference; or removed from the building set completely and submitted as a reference copy of the approved and signed development package. 3. COMMENT: Once the plans have been approved by all Commercial Plans reviewers and no site changes are made that affect zoning requirements, zoning will stamp and sign the building plans as it pertains to the zoning review purview. If you have any questions about this transmittal, Contact Michael.Moreno@Tucson.az.gov at any time during the week |