Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T18CM02009
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/16/2018 | MCASTRO2 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: Mark Castro Lead Planner PROJECT: T18CM02009 211 S Busch Pl. Detached Carport TRANSMITTAL: 3/16/18 COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1). This site is located in the R-1 zone (UDC 4.7.9). Single-family residential is a permitted use in this zone (Table 4.8-2). ). See Use Specific Standards 4.9.7.B.6, .9 & .10. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The applicant is proposing to construct a detached carport. Based on a wall height of 18', the required setback to east and south lot line is 11'-11", the proposed setback to the east lot line is 3'-7" and 0' to the south lot line. Accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. If attached to the principal structure, maximum height permitted shall be the same as for the principal structure. The applicant is proposing to construct a detached carport 20'-8" as measured from design grade to the midpoint of the pitched roof. B/A variances required. The existing garage at the north part of the property was not permitted. The garage does not appear setbacks to the north lot line and west lot line. Setbacks cannot be verified until elevation drawings are provided to verify square-footage and height. |
| 03/16/2018 | MCASTRO2 | ZONING | REVIEW | Reqs Change | P&DS TRANSMITTAL FROM: Mark Castro, Lead Planner PROJECT: T18CM02009 211 S Busch Pl Attached Carport TRANSMITTAL: 6/06/18 **REVISED** COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The applicant is proposing to construct an attached carport. Based on a wall height of 16', the required setback to east lot line is 10'-7". The proposed setback to the east lot line is 2' and 5'. Based on a wall height of 21'-4", the required setback to the south lot line is 14'-1". The proposed setback to the south lot line is 1'. DDO approval is required for reduced setbacks. |
| 07/17/2018 | QJONES1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review | |
| 07/17/2018 | QJONES1 | ENGINEERING | REVIEW | Needs Review |