Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM01830
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/26/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet CV; Building Code: The City of Tucson did not adopt the 2015 International Codes or the 2014 NEC. Please revise to the 2012 International Codes and the 2011 NEC, or appeal the building official to use the 2015 Codes as listed. 2. Sheet CV; Occupancy Allowance: The 2000 IBC Code is referenced here. Please revise. 3. Sheets AS1-AS3: The City of Tucson requires all lettering (upper and lower case) be a minimum of 3/32" in height. Many of the details that do not pertain to this project could be removed to create more room. 4. Sheet SD2; Details 1 and 2: Both of these details do not list the wind speed or design loads. Please reference Sheet FD1 for thos values. 5. Sheet SD2; Digital Menu Board and Foundation: The calculations for the foundation design are included with this submittal. Please indicate on the foundation detail the information given in the structural calculations for the foundation (Page 28) and the anchor bolts (Page 30), or reference Sheet FD1 for that information. 6. Sheet SD2; Pre-Browse Board and Foundation: The calculations for the foundation design are included with this submittal. Please indicate on the foundation detail the information given in the structural calculations for the foundation (Page 23) and the anchor bolts (Page 30), or reference Sheet FD1 for that information. 7. Sheet SD3; Clearance Gateway Details A, B, and C: No structural calculations were located for the foundation or anchor bolt design in this submittal. Please provide. 8. Sheets SD3 and SD4: The City of Tucson requires all lettering (upper and lower case) to be a minimum of 3/32" in height. Please revise. 9. Sheet SD4; Yard Light Detail: Please indicate the maximum height of the light pole on this detail. 10. Sheet SD4; Yard Light Detail: Please include copies of the relevant sheets from the AASHTO Standard Specifications (indicated on this detail) for the foundation and anchor bolt designs. 11. Sheet SD4; Order Here Canopy Details A, B, and C: Please provide the structural design calculations for the foundation and anchor bolts. 12. Sheet A0.2; Demolition Keynotes: Note 7 was not located on the plan. Please verify. 13. Sheet A1.0; Partition Detail 2: Please clear up the verbiage in the upper right of the detail. 14. Sheet A1.0; Partition Detail 2: Please indicate the lateral bracing size and the size/quantity of connectors. Extend the detail to show how the brace connects to the structure above. Another option is to reference a structural detail if applicable. 15. Sheet A1.0; Partition Detail 2: The wood stud "D1" references Detail 3/A1.0. Please revise that reference. 16. Sheet A1.2; Key Notes: Notes 2 and 11 were not located on the plan. Please verify. 17. Sheet A2.2; Demolition Keynotes: Note 4 was not located on the plan. Please verify. 18. Sheet A4.0; Elevation 16: The horizontal grab bar on the side wall elevation is not marked as 1A. Please provide. 19. Sheet A4.1; Section 12: The City of Tucson requires all lettering (upper and lower case) to be a minimum of 3/32" in height. Please revise the dimensions. 20. Sheet A5.1; Sections 4, 12, and 20: At the new roofing, please indicate the joist size and spacing, or reference the structural plans/notes/details that have that information. 21. Sheet A5.2; Section 20: At the new roofing, please indicate the joist size and spacing, or reference the structural plans/notes/details that have that information. 22. Sheet A5.3; Detail 15: Please indicate the lateral bracing size and the size/quantity of connectors. Extend the detail to show how the brace connects to the structure above. Another option is to reference a structural detail if applicable. 23. Sheet S1.1; Notes: The City of Tucson requires all lettering (upper and lower case) to a minimum of 3/32" in height. Please revise. 24. Sheet S1.1: Please provide notes for soil bearing and lateral resistance values used in the pier design, or reference Sheet FD1. 25. Sheet S1.2: The City of Tucson requires all lettering (upper and lower case) to a minimum of 3/32" in height. Please revise. 26. Sheet S3.0; Section 12: Is the Detail 5/S4.1 at the new sun screen correct? That detail appears to apply at the canopy. Please verify. 27. General: Please provide written responses to all review comments. |
| 03/26/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 03/26/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 03/26/2018 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 03/26/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 04/04/2018 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera PDSD Zoning Review Section PROJECT: T18CM01830 - T.I. Renovation- Drive Through and Interior Remodel (Food Service Use) Building Plan Review (1st Review) - McDonalds 30 S. Houghton Road TRANSMITTAL DATE: April 4, 2018 DUE DATE: April 9, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: Zoning has done a review of the building plans but cannot approve them at this time. While the proposed building and site changes appear to be in compliance with the zoning requirements and accessibility requirements zoning cannot approve the plans at this time. On sheet SD1 the sign detail 6 needs to be revised to state the minimum clearance from the sidewalk to the bottom of the sign must be 84 inches. 2. COMMENT: While the interior remodel and facade modifications do not affect any zoning requirements, prior to approval of the building plans by Zoning, the plans must be approved by all Commercial plans reviewers. 3. COMMENT: Zoning will review the building plans on the next submittal to assure that the zoning comments have been addressed on the plans. Once all zoning comments have been addressed and the plans have been approved by all commercial plans reviewers zoning will also approve and stamp the plans. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: building plans |
| 04/06/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. #1. The Outdoor Lighting Lumen calcs must include the existing site lighting. Section 104.2.1 OLC. #2. Ref: Plan Sheet E2.0. The canopy luminaires per Keyed Note #8 needs to be included in the Outdoor Lighting calcs and luminaire schedule. Also must be assigned or identified with a mark. #3. Provide compliance with section 402.1 for light source color output temperature. #4. Assign branch circuit numbers and panel designations for all new or relocated outlets shown on the electrical floor plans. #4. Provide a complete one-line diagram of the electrical service and show any modifications. Indicate new or existing equipment. #5. Provide complete panel schedules including load calcs. Ref: 2012 IBC 107.2.1, 2011 NEC, Tucson/Pima County Outdoor Lighting Code. |
| 04/10/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approv-Cond | Once all other department comments have been addressed and the plans have been approved by all commercial plans reviewers Engineering will also approve and stamp the plans. John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/17/2018 | QJONES1 | APPROVAL SHELF | Completed |
| 04/17/2018 | QJONES1 | OUT TO CUSTOMER | Completed |
| 04/17/2018 | QJONES1 | REJECT SHELF | Completed |