Permit Number: T18CM01546
Parcel: 14027042C

Address:
2622 E BILBY RD

Review Status: Active

Review Details: RESUBMITTAL

Permit Number - T18CM01546
Review Name: RESUBMITTAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
07/23/2018 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change A COMcheck analysis for the building envelope was not included with the first submittal and is not part of the current submittal. [Initial comment: The energy use of the building appears to be about 1.5 Watts per square foot. Provide a COMcheck analysis for the building envelope. Reference: Section C101.5.2 and C401.2, IECC 2012.]
07/23/2018 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
07/24/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
08/01/2018 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following electrical plan review comments. Also provide a written response.
#1. As per the last electrical plan review comment. "#1. Designate a branch circuit and panel for the Evap cooler maintenance receptacles. If they are sharing the pump circuit, please indicate this on the plans". A code reference was provided by the reviewer NEC 408.4, States, "FIELD IDENTIFICATION REQUIRED
Every circuit and circuit modification shall be legibly identified as to its clear, evident, and specific purpose or use. The identification shall include sufficient detail to allow each circuit to be distinguished from all others……. The identification shall be included in a circuit directory"… As per the response, " The receptacle circuits are clearly shown on sheet E3 and on the panel schedules".
The plan reviewer double checked the re- submittal and there is no circuit indicated on plan sheet E3, and the panel schedules making any reference of cooler maintenance receptacles. Furthermore it was noted that GFI protection was not provided for as required per NEC 210.8b(4). The receptacle symbol used on the plan does not correlate with the symbol for GFI on the symbol schedule E1, Nor was it identified as GFI protected on the plans. Please address this.
Ref; 2012 IBC 107.2.1, 2011 NEC
08/02/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section
PROJECT: T18CM01546 - New Building (Storage Use)
Building Plan Review (2nd Review) - Bilby Warehouse
2622 E Bilby Road
TRANSMITTAL DATE: August 2, 2018
DUE DATE: August 13, 2018
COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. COMMENT: Zoning has done a cursory review of the building plans. Prior to a more comprehensive review by zoning the Approval of the Revised DP is required. While the cursory review did yield an indication that the building plans are consistent with what has been proposed and drawn on the DP (that has been submitted for review) zoning cannot approve the building plans at this time.
As of this second review of the building plans, the DP has not been re-submitted for review. The DP needs to be submitted for review and approval before zoning will approve the building plans.
2. COMMENT: Zoning will review the building plans on the next submittal to assure consistency with the approved DP. If any changes are necessary to the building plans due to plan review comments that affect zoning requirements, the DP will have to be revised to reflect the changes. Once the DP is approved by all reviewers and the building plans are approved by the Commercial Plans reviewers zoning can approve the building plans.
3. COMMENT: Zoning will refer to the approved Development Package for reference and compliance. Include as reference a copy of the approved DP with the next submittal. If the DP has not been scanned at PDSD and not available for review as reference include a hard copy as "reference only" with the building plans. (Do not attach the DP or make them part of the building plans package.)
If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: building plans
08/09/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change T18CM01546

1) A general review of the building plans was conducted and appears to be in compliance with first submittal of DP17-0237. Final approval of building plans requires that the open comments relating to the DP are addressed and the DP approved. An additional review of the building plans will be conducted once the DP has been approved.

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007

Final Status

Task End Date Reviewer's Name Type of Review Description
07/16/2018 ANY REJECT SHELF RECEIVED