Permit Number: T18CM01135
Parcel: 12217365A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T18CM01135
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/23/2018 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet CVR; Building Code Summary: This project consists of an addition to an existing dining center/restaurant. Please clarify on this sheet the square footage of the addition and the occupant load for the addition. A new C of O will be provided for the addition only, and the area/occupant load should be listed separately.
2. Sheet SD-1; Site Plan: To the north of the addition, an existing structure 5 is indicated. Per the IBC Table 602, is the new addition required to have a fire resistance rating for the exterior walls due to the separation distance from the new addition to that structure 5? Please verify and indicate the separation distance on the plan.
3. Sheet A-1 (Wall Construction Notes); Sheet CVR (Code Summary): A note on Sheet CVR indicates all new exterior walls to be one hour fire resistance rated. The proposed exterior wall construction note does not indicate a one hour rated wall. Please indicate a UL listing number for the new exterior walls on Sheet A-1.
4. Sheet A-1; Notes: Note 2 indicates "All door styles to be selected by owner". If the new exterior walls are fire resistance rated, the door must also be rated per the IBC Table 716.5. Add this information to the Note 2.
5. Sheet A-1; Notes: Note 1 discusses door hardware. Per the IBC Section 1008.1.10, panic hardware is required in Group A occupancies if the occupant load in the space is 50 or more. Please indicate this information in Note 1, or provide on the drawing the exception to this requirement per Section 1008.1.9.3(Item 2).
6. Sheet A-2; East Elevation: The title for this elevation should be "C". Please revise.
7. Sheet D-1 (Details 1 and 4); Structural Calculations (Footing 3): The City of Tucson requires a minimum of 18" deep footing (from finish grade to bottom of footing) to get 1500 PSF allowable soil bearing, or a minimum of 12" deep footing to get 1000 PSF. The details indicate a minimum 12" depth, but the soil bearing value is 1500 PSF. Please revise. Add a note to Sheet S-1 for the allowable soil bearing.
8. Sheet D-1; Detail 3: A note indicates "Door and frame per schedule". There is no door schedule. Please revise the note.
9. General: Please provide written responses to all review comments.
03/23/2018 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved
04/03/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: T18CM01135
Building Addition (2nd Review)
1550 N Country Club Road

TRANSMITTAL DATE: April 3, 2018

DUE DATE: April 5, 2017

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. COMMENT: Zoning has done a courtesy review of the proposed building addition /expansion but cannot approve the building plans at this time. Per the Zoning reviewer comments at time of the building plan submittal, a revised DP is required before approval of the building plans by zoning. It is acknowledged that a revised DP was approved.


2. COMMENT: The proposed building plans expansion is minimal and could be reviewed over the counter by zoning assuming the DP is revised and approved ahead of time and all the PDSD Commercial Building Plan reviewer has also approved the building plans. Assure that a copy of the revised and approved DP is available when the building plans are resubmitted for review or if an over the counter review is possible.


3. COMMENT: Zoning will do another building plan review on the next submittal to verify consistency with the revised and approved DP.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans

Final Status

Task End Date Reviewer's Name Type of Review Description
04/09/2018 QJONES1 APPROVAL SHELF Completed
04/09/2018 QJONES1 OUT TO CUSTOMER Completed
04/09/2018 QJONES1 REJECT SHELF Completed