Permit Number: T18CM00844
Parcel: 14042075B

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T18CM00844
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/02/2018 MCASTRO2 ZONING REVIEW Approved
02/02/2018 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Provide source capture exhaust at locations where nail polish is applied.
2. Do not recirculate air from a nail salon to other occupancies.
02/02/2018 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
02/02/2018 MCASTRO2 ENGINEERING REVIEW Passed
02/02/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide backflow protection for each pedicure chair (HW & CW)
2. Show a dirt leg on the gas line feeding the water heater in detail 201
02/02/2018 ROBERT SHERRY WATER REVIEW Completed
02/02/2018 JVINCEN1 FIRE REVIEW Approved
02/06/2018 QJONES1 BUILDING-COMMERCIAL REVIEW Needs Review
02/06/2018 QJONES1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
02/06/2018 QJONES1 APPROVAL SHELF Completed
02/06/2018 QJONES1 OUT TO CUSTOMER Completed
02/06/2018 QJONES1 REJECT SHELF Completed