Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T17PI00039
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2017 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | I see that you reduced the understory planting along 7th for pedestrian access to the sidewalk - thank you. Please do the same for planting between curb and sidewalk along 5th. You are removing 8 Blue Palo Verde stating they are too close to the curb, and yet you are coming back in planting large tree 2' off the curb - and 5' off the building. ????? You will need to add TDOT's standard notes for planting in the ROW. Please call or e-mail me for those. 837-6618 gary.wittwer@tucsonaz.gov Please submit an irrigation plan - see notes for planting in ROW for irrigation requirements. |
| 10/30/2017 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | Please see redline comments. Redline drawing sent to Derek Willson on 10-30-17 |
| 10/30/2017 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | October 30, 2017 SUBJECT: 7th Avenue Commons PIA Plan T17PI00039 PROJECT REVIEWER: Zelin Canchola, TDOT Review Section DOT Review Section has reviewed the PIA Plan for Traffic Engineering. The proposed striping and signing is acceptable. However the width of the roadway travel lanes does not meet minimum standard of 12 feet. Eliminate angled parking on the east side of the road on 7th Avenue. Add/maintain parallel parking along east side of 7th Avenue. 1. Add type and size of striping for the parking. 4 inch is typical; with thermoplastic paint. 2. Add new Stop sign at North Echols Ave and 5th Street. Restore or replace street name signs. 3. No parking will be allowing on Echols Ave. Install No Parking signs. 4. Add General notes for pavement marking plans from PCDOT and TDOT Traffic Engineering division Sheet 2-1 (Pavement marking design manual) If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 11/01/2017 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | NO FURTHER COMMENTS - PAUL BURTON 10/31/17 |
| 11/13/2017 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 11/13/2017 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |