Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T17PI00036
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/11/2017 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approv-Cond | A full irrigation system design was not submitted. If you are not crossing the new public streets, then you are approved. If the irrigation system needs to cross the new public street then you must resubmit that design and get an easement to cross the road. |
| 09/20/2017 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | September 19, 2017 SUBJECT: S. 6th Av and E. Medina Rd PIA Plan: T17PI00036 PROJECT REVIEWER: Zelin Canchola, DOT Review Section RESUBMITTAL REQUIRED: DOT Review Section has reviewed the PIA Plan for Traffic Engineering. 1. Provide striping plan for 6th Ave. new white striping required. Maintain alignment of existing white striping south of Medina. 2. Add general notes for pavement marking. 3. List quantities and descriptions. 4. Remove stop sign on E. Manor View Rd. @ S. Desert Manor Av. 5. Remove stop sign on S. Manor View Ct. @ E. Manor View Rd. 6. Page 6 of 7. Keynote 22 shows two arrows, one pointing to proposed stop sign location, the other to the opposite curb line. Eliminate the second arrow pointing to the curb. If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 09/26/2017 | CSALTZM1 | DOT ENGINEERING | REVIEW | Reqs Change | 1) Sht. 1 of 7 - Top center of sheet add Ave. to 6th and Rd. to Medina 2) Sht. 1 of 7 - Top center of sheet add PIA No. T17PI00036 3) All sheets - Add PIA No. T17PI00036 lower rt. corner above signature block. 4) Sht. 2 of 7 - left curb profile add percent slope to curb. 5) Sht. 3 of 7 - show vertical curve info for Lt. and Rt. Curbs 6) Sht. 5 of 7 - S. Manor View cul de sac Sta. 3+50 add Barricade Rail where slope is 2:1. 7) Sht. 6 of 7 - CL Profile: Is the profile at the center line or at 10.84 Lt.? 8) Sht. 7 of 7 - PAVING NOTES: Note No. 1 calls out the 2003 Standards Specifications for Public Improvements. Remove the 2003 Std. Specs. and use the 2015 PAG Std. and Specs for Public Improvements for this project. 9) Sht. 7 of 7 - Details 7 and 7A: use the PAG 2015 access Ramp details with the 5'X5' level landing. 10) Sht. 7 0f 7 - DETAIL 5 SCUPPER DETAILS: Detail A SIDEWALK SCUPPER TYPE 3: need to show slope of spillway DETAIL B: need to show slope of scupper DETAIL C: need to show slope of scupper 11) All sheet showing sewer trench patch need dimensions (width, distance past manhole). 12) Geotechnical Exploration Recommendations for Medina Rd. - 6th Ave. report needs to address the pavement structural design section. 13) Geotechnical Exploration Recommendations for Medina Rd. - 6th Ave. report - Section 5.5.2 Site Preparation paragraph 6 identifies collapsing soils. The plans need to address the condition and remediation. |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 09/28/2017 | LPETERS2 | DOT PERMITS & CODES | REVIEW | Denied | I have reviewed this plan and have the following comments: 1. Sheet 7 - Note 1 - We are curretnly using the 2015 PAG Standards and Details. 2. Sheet 7 - Note 3 - The City of Tucson has gone to a TDOT Mix number 2 instead of the PAG No. 2 mix. 3. Sheet 7 - Notes - We should have a note stating that prior to disturbing vegetation in the right of way, Gary Wittwer at 791-5100 should be contacted. 4. Sheet 7 - Detail 2 and 2A - This shows AB compacted to 95%. This should be 100% No further comments Lance Peterson 837-6777 |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 09/28/2017 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 09/29/2017 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | |
| 09/29/2017 | ERNIE ENCINAS | DOT_ELEC | No objections or comments | Approved | |
| 10/02/2017 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Denied | Medina should be milled and overlayed between 6th and S Desmanor, due to number of sewer cuts in an already poor road. James Femling Streets & Traffic Maintenance Division 10/02/17 |
| 10/02/2017 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 10/02/2017 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |