Plan Review Detail
Review Status: Completed
Review Details: PIA - RESUBMITTAL
Plan Number - T17PI00027
Review Name: PIA - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 09/21/2017 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 09/22/2017 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Approved | Change speed limit on Drexel to 30 mph. |
| 10/11/2017 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | 1. TDOT will not allow open curb cuts on roads with design speed over 25 MPH. Change opennings to scuppers with a continuous curb line. 2. Add TDOT standard notes for planting in ROW. Call me if you do not already have them. 837-6618 3. We need to develop a Formal License Agreement per the PAD for Landscape and Irrigation long term maintenance prior to approval. 4. Understory is over planted, large shrubs planted close to curb line or bullnose of median will eventually cause SVT issues and maitenance issues. 5. Private irrigation lines under public roadways must follow TDOT requirements. Please e-mail or call me for those requirements. |
| 10/27/2017 | RICHARD LEIGH | DOT PERMITS & CODES | REVIEW | Reqs Change | October 27, 2017 SUBJECT: Paving and Striping Plans for Saguaro Trails - Drexel Road PROJECT REVIEWER: Richard Leigh, TDOT Engineering Review, 2nd RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to final approval. Please include a response letter addressing the following comments and return any redlined drawings with subsequent submittal. 1. Include all lines used in drawing in legend. 2. Clearly label all proposed easements and indicate easement purposes. 3. Verify that all keynotes used are in keynote legend. 4. Verify that roadway sections are representative of the proposed roadway. 5. Reduce the number of irrigation line crossings. Easements will be required for each crossing along with TDOT placement requirements. See attached. 6. Maintenance of water harvesting areas shall be the developer's responsibility. Flowage easements shall be provided at scuppers accepting roadway runoff. Provide public drainage easements at inlet and outlets of culver crossings. 7. Curb opening longer that two feet will not be permitted. Sidewalk scuppers per PAG Standard Details or equivalent will be required for curb openings wider than two feet. Stormwater catchment areas shall not be within two feet public roadway pavement structure. Any catchment areas proposed within ten feet of the pavement structures will require a soils engineering setback assessment. 8. Indicate the placement of an eight foot wide graded shoulder on the south side of Drexel Rd between Stations 100+00 to 103+50. 9. All sidewalk and curb access ramps along Houghton Rd shall be a minimum six foot wide. 10. Please Refer to redline drawings for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or emailed at Richard.Leigh@tucsonaz.gov ________________________________________________ City of Tucson, Department of Transportation Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way " Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways. " Lateral lines under constant pressure shall not be permitted in the public rights-of-way. " The HOA will register private irrigation facilities placed in the public rights-of-way with Arizona 811and become an Arizona 811 Blue Stake Inc. member. " Minimize the number of roadway crossings. " Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting. " Irrigation lines shall be placed in ductile iron sleeves. " Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT. " HDPE continuous line (no joints under the pavement) " Irrigation lines shall have a minimum of thirty (30) inches of cover. " Detectable marking tape shall be installed. " Curb shall be marked/stamped with "IS" (Irrigation System) and/or placard at back of curb. |
| 10/27/2017 | ELEIBOL1 | DOT ENGINEERING | REVIEW | Reqs Change | TO: Ryan Stucki, P.E., EEC SUBJECT: PIA Review: Saguaro Trails - Drexel Road T17PI00027 / I-2017-009 The following items need clarification: 1- need specific flowrates for pre- and post development at each proposed outlet 2- explanation of whether the proposed outlet is located at a pre-existing conveyance location matching existing flow patterns 3- explanation of any future proposed landscaping buffer or other new waterharvesting area 4- associated maintenance responsibility explained for waterharvesting or slope easements (each easement needs to be labeled as public or private) 5- soils engineering setback assessment for any proposed catchment within 10-feet of public pavement structures 6- explanation of reason for changed design from initial submittal. [Ref: Tech Man Sec.4-04.2.3.1.4, 1.51] Elizabeth Leibold P.E., CPM, CFM Engineering Review Division Department of Transportation https://www.tucsonaz.gov/tdot/engineering City of Tucson (520) 837-4934 (office) |
| 11/20/2017 | LINZUNZA | DOT MAPS & RECORDS | REVIEW | Denied | |
| 11/20/2017 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 11/20/2017 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |