Plan Review Detail
Review Status: Completed
Review Details: PIA - RESUBMITTAL
Plan Number - T17PI00022
Review Name: PIA - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/30/2017 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | Reviewed resubmitted plans - no descrepencies noted |
| 06/08/2017 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Reqs Change | Hi Donna, Thank you for sending me the submittal. Generally, looks very good. A do have a couple minor comments: 1) For the street name sign at Warren/7th Street please delete the cardinal direction and use the following: Warren Ave 400 N 7th St 1700 E 2) I did see the arrow pointing to the "cradle" in the street name sign mounting detail. There is significantly more detail regarding the cradle in the drawing I sent Bob Alcala, but if the information is in the Special Provisions, then I don't think it needs to be included on the plan set. 3) I noticed the new FLOOD HAZARD AREA signs, and I suspect these 18x18 warning signs are intended for pedestrians crossing the alley alignment when flooded. Am I correct? If so, I suggest a black-and-white (regulatory sign) that reads "NO PEDESTRIAN CROSSING WHEN FLOODED." It would be similar to the MUTCD R9-3a. Pedestrians are accustomed to ignoring signs posted for motor-vehicles so I am suggesting this sign message that makes it clear that the message is directed to pedestrians. They are not in the public right-of-way, but I am bemused by the NO PARKING WHEN FLOODED | FLOOD HAZARD AREA, because if you park in the morning, and it floods in the afternoon, and you car is surrounded by water ... well, you were warned, I suppose. Technically, a "NO PARKING" message is a regulatory message and is more appropriately used on a regulatory sign. My suggestion for this sign is "FLOOD HAZARD AREA | PARK AT YOUR OWN RISK." Let me know if you have any questions. I am out of the office tomorrow and Monday, Memorial Day holiday. Diahn Diahn L. Swartz, P.E., PTOE Traffic Engineering Manager City of Tucson 201 N. Stone Ave, 5th Floor PO Box 27210 Tucson AZ 85726-7210 (520) 791-4259 (520) 791-5526 (fax) Diahn.Swartz@tucsonaz.gov |
| 06/08/2017 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 06/08/2017 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |