Plan Number: T17PI00009
Parcel: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T17PI00009
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/18/2017 LINZUNZA UTILITY CLEARANCES COT STREETS DIVISION Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES PC WASTEWATER MGMT Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES QUEST COMMUNICATION Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES COX COMMUNICATION Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES EL PASO NATURAL GAS Denied
01/18/2017 LINZUNZA UTILITY CLEARANCES KINDER MORGAN ENERGY Denied
01/20/2017 LPETERS2 DOT PERMITS & CODES REVIEW Denied I have reviewed this plan and have the following comments:

1. Sheet 1 - The plan references PC/COT SSPI. Is this the standards that this is to be constructed under or the new PAG volume 1 standard specification?
2. Sheet 1 - Typically a note include to contact Street Supervisor Paul Rosenboom prior to disturbing any city owned landscaping or irrigation.
3. Sheets 2 - 3 - Plans show several curb access ramps but does not specify type. Elevations are provided but not outs.
4. Sheet 2 - Plan refernecs to see sheet 4 for continuation of the plan. Sheet 4 only contains details.
5. Sheet 4 - Detail 1 Pavers - This detail does not meet our standard with respect to installing pavers. Is there a reason why the standards specification for pavers isnt used?

No further commetns.

Lance Peterson, P.E.
(520) 837-6777
02/09/2017 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
02/15/2017 GARY WITTWER DOT LANDSCAPE REVIEW Denied 1. Please clearly identify the ROW on all plans and details.
2. Please submit the landscape plans if there is any new planting in ROW.
Per the Downtow Streetscape Policy the main pedestrian walk area is to be concrete. Let me know if you do not have a copy of this policy
02/16/2017 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved NO COMMENTS - APPROVED BY JFEMLING 2/16/17.
02/22/2017 LINZUNZA PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
02/22/2017 RICHARD LEIGH DOT ENGINEERING REVIEW Denied February 21, 2017


SUBJECT: Mission District of Menlo Park Public Improvement plans, Monier Building
U-2017-002 - T17PI00009

PROJECT REVIEWER: Richard Leigh, TDOT Engineering Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to final approval. Please include a response letter addressing the following comments and return any redlined drawings with subsequent submittal.

1. Sheet 1: Include the plan number "U-2017-002" in the title block of each sheet.

2. Sheet 1: Include the PIA activity number "T17PI00009" on cover sheet.

3. The City of Tucson has adopted the Pima Associates of Government (PAG) 2015 Standard Specification for Public Improvements (SSPI) and Standard Details (SD). Please revise plan set to reflect this change.

1. Plans must contain all the information necessary to build project as a "stand alone" project and not rely on references to other plans. Please provide all details of the proposed improvements in the public rights-of-way.

4. Provide stationing, offsets and elevations for all beginning and ending curb returns and angle points and all other proposed improvements.

5. Clearly delineate and label public right-of-way limits and any existing easements within the rights-of-way.

6. Provide a minimum 5' wide unobstructed sidewalk the projects frontage.

7. Please Refer to redline drawings for additional comments and comment details.

If you have any questions, I can be reached at 837-6647 or emailed at Richard.Leigh@tucsonaz.gov.
02/22/2017 LINZUNZA PIA COORDINATOR OUT TO CUSTOMER Completed