Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T17OT00219
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/28/2017 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | The use a portion of the FEMA Special Flood Hazard Area Zone A per the Flood Insurance Rate Maps 04019C1693L, specifically described as: A Portion of Parcel 111-01-035D; PTN SE4 NE4 27.62AC SEC 28-13-14 For the purpose of constructing 122 KW DC Solar Carport The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 8 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the Solar Carport, or, if there is any further disturbance within the floodplain and W.A.S.H. overlay other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of a shed within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) All work shall conform to the approved Details and General site plan sheets for the construction of the Solar Carport, which are made part of this permit. The Solar Carport will be open on all sides per the detail to allow water to flow through, it will also be anchored per the detail. 4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T17OT00219 FOR INFORMATION PLEASE CALL 791-5550." 5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) See the associated activity T17CM01579 8) This permit is specific to the improvements for 3718 E River Road as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. |