Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T17OT00116
Parcel: 12217248B

Address:
1664 N JONES BL

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - FLOODPLAIN

Permit Number - T17OT00116
Review Name: PLANS OK TO SUBMIT - FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/10/2017 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: February 10, 2017
DUE DATE: February 15, 2017
SUBJECT: NEW SFR
TO: Noric Construction and Development.
LOCATION: 1664 N Jones Blvd
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: T17CM00713 and T17OT00116
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Per Tucson Code 26-5.2(8) show that the finished floor elevation is one foot above the base flood elevation. - Base Flood Elevation is 2451.54 and FFE will need to be 2452.54.
2) Per Tucson Code 26-5.2(11) show all service facilities such as electrical and heating equipment at or above the regulatory flood elevation. The Regulatory Flood Elevation is 2452.54.
3) If at least two feet of fill is being placed on any location within the site show compliance with 2-01.8.1. If less than two feet of fill is being placed on the site add a general note indicating that less than two feet of fill is being added.
4) Per AM 2-06.4.8I show the 100-year floodplain limits and the 100-year water surface elevation upstream of each structure being proposed.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.