Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Permit Number - T17CM09408
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/10/2018 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). For 18' 7" and 22' 5", the required setback is 9' 3" on the west side 14' 9" on the east side and the proposed setback from the building is 6' 2" on the east and west side. The proposal also includes exterior stairs on the east side within the required setback. |
| 01/12/2018 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | Floodplain Use Permit required. |
| 01/24/2018 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed |