Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T17CM09187
Parcel: 11105262A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T17CM09187
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/07/2018 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Previous Comment 5; Restroom Locations: This was submitted to the Building Official on 2-7-18 for an appeal.
2. Previous Comment 9; Exterior Partition Type 6B: The stud size and spacing are required, or provide a reference for that information.
3. Previous Comment 11; Drinking Fountain: The required drinking fountain (high/low or single point of use per the Code Study on Sheet TS1) has not been located on the drawings. Please provide and add a Key Note.
4. Previous Comment 12; Shade Detail (4/A4.0): The top angles indicate 3 x 3 1/2 on the detail, while the framing plan (Sheet S3.0), indicates a 3 1/2 x 3 1/2. Please coordinate.
5. General: Please provide written responses to all review comments.
02/07/2018 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Comment not addressed; provide COMcheck calculation for the alteration of the building envelope. [Initial comment: Demonstrate energy code compliance for the alterations to the building envelope based on the current code (e.g. doors, windows, and skylights). Reference: Sections C101.4.3, C101.5, C103.2, C303, and C401.2.1, International Energy Conservation Code 2012]
2. Comment not addressed. [Initial comment: Provide heating and cooling load calculations that justify the capacities of the heating and cooling equipment specified for the project. Reference: Sections C403.2.1 and C403.2.2, IECC 2012, and Section 312.1, IMC 2012.]
3. Provide an exhaust duct for the proposed clothes dryer. Reference: Section 504.6.6, IMC 2012.
02/07/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The gas line to the northern RTU is still incorrectly labeled as EXIST ½". [Initial comment: Verify the sizes of the existing natural gas piping. The gas main is incorrectly labeled as EXIST. ½" in several locations and the gas line to the northern RTU is also incorrectly labeled as EXIST ½" Reference: Section 402.3, IFGC 2012.]
2. The sediment trap is still located upstream of the shut off valve. [Initial comment: Revise detail 2/P3.2 to show the location of the sediment trap downstream of the appliance shut off valve, as close to the equipment as possible. Reference: Section 408.4, IFGC 2012.]
3. Comment not addressed. [Initial comment: Provide the minimum plumbing facilities required by Table 2902.1, IBC 2012, for business occupancy (i.e. drinking fountains). Reference: Sections 1109.5 and 2902.1, IBC 2012.]
02/07/2018 ROBERT SHERRY WATER REVIEW Completed
02/14/2018 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Benarda Veterinary Hospital
Building Plan (1st Review)
T17CM09187

TRANSMITTAL DATE: February 14, 2018

DUE DATE: February 15, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. 2-06.4.9.H.5.a - As the restriped accessible vehicle parking space is required to be a van accessible vehicle parking space, see 2012 IBC Chapter 11 Section 1106.5, per ICC A117.1-2009 Section 502.4.1 the access aisle is required to be on the passenger side of the angled accessible parking space.

2. 2-06.4.9.H.5.a - Demonstrate on the plan that the accessible space meets the requirements of ICC A117.1, Section 502.2.

3. 2-06.4.9.R - Demonstrate on the plan that the accessible route from the accessible vehicle parking space meets the requirements of ICC A117.1, Section 403.3.

4. 2-06.4.9.R - It appears that the striped access route from the accessible vehicle parking space to the building runs into the proposed "3' HIGH BARRIER" shown along the west side of the proposed "NEW SIDEWALK". Demonstrate on the plan that a minimum 4' wide access is provided.

5. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve.

Once the above comments have been addressed Zoning is willing to provide and over-the-counter review. Call or email to schedule an appointment for this review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
02/22/2018 KROBLES1 ENGINEERING REVIEW Needs Review