Permit Number: T17CM08944
Parcel: 138191980

Address:
6629 S 10TH AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T17CM08944
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: T17CM08944
New Single Family Residence (1st Review)
6629 S. 6th Avenue

TRANSMITTAL DATE: January 4, 2018

DUE DATE: January 4, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. COMMENT: Zoning has reviewed the building plans for the proposed new Single Family Dwelling but cannot approve the plans at this time. Please address the following comments and resubmit for review or the plans can be reviewed and approved over the counter once the corrections have been made.


2. COMMENT: In order to verify that the street perimeter building setbacks have been met, label the overall heights on the elevation drawing facing the street. This elevation has two elevation walls one shorter than the other. The street perimeter building setback is based on the greatest of 20 feet or 1.5 times the height of the wall facing the street property line. Based on scaling the drawing the minimum setback along the front must be 23'-3" to the tallest wall measured from design grade (adjacent ground) to the top of the gable end just under the eave of the roof.

Label the overall height of the side yard building elevations from design grade to the top of the top plat. While the side yard setbacks appear to meet the setback the height shall be labeled for verification.


3. COMMENT: Draw, label and dimension the center of the street and curb location.


4. COMMENT: See redlines on sheet one and two.


5. COMMENT: Once the changes are made the plans can be reviewed over the counter and if all the zoning comments have been addressed the plan can be approved by zoning.


If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
12/20/2017 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
01/16/2018 ARUIZ1 OUT TO CUSTOMER Completed