Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T17CM08581
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/17/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
11/17/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
11/28/2017 | MARTIN BROWN | FIRE | REVIEW | Approved | |
12/07/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. General Sheets; G0.5 and G0.6: These sheets are not listed on the Sheet G0.1 Drawing Inventory. Please clarify. Should Sheets G0.5 and G0.6 be inserted to Sheet G0.1? 2. Sheet A0.4; Second Level Plan: The IR LAB 3 (0250803) has an enlarged plan reference 1/A7.2.11. Please revise that reference. 3. Sheet A2.2.0; Second Level Plan: In the IR LAB 3 (0250803), hatching has been indicated. Please add a Graphic Legend to this sheet indicating the description of that hatching. 4. Sheet A2.2.3D; Second Level Plan: In the CATH LAB 2 (0250902), please adjust the room title so it is legible. 5. Sheet A3.2.3; Second Level Plan: In the CATH LAB 1 and 2 (0250901 and 0250902), please adjust the room titles so they are legible. 6. Sheet A3.2.4; Second Level Plan: Please add the room titles to EP1 and EP2. 7. Sheet A7.2.12B; Enlarged Plans 1 and 2: Hatching has been indicated on these plans. Please add a Graphic Legend to this sheet indicating the description of that hatching. 8. Sheet A7.3.4: This sheet was included in the submittal set, but was not indicated on the Itemized List. Please verify. 9. Sheet AQ2.2.4D; Second Level Plan: Hatching has been indicated on these plans. Please add a Graphic Legend to this sheet indicating the description of that hatching. 10. General: Please provide written responses to all review comments. |
12/15/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | BANNER MODALITIES ROUND 3 COMMENTS Please address the following electrical plan review comments. Also provide a written response. #1. Provide revised IECC Energy Code Compliance for the added lighting. #2. Plan sheet E7.0.1 (Details) shown on itemized list, not included in the plan set. #3. What do the hexagon symbols with letters inside represent, shown in the enlarged electrical floor plans? Provide a complete symbol legend and a equipment schedule. #4. Provide complete panel schedules for all the panels associated with the circuiting of all the equipment and devices shown on the enlarged power and lighting plans. Ref; 2012 IBC sec 107.2.1, 2011 NEC |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/19/2018 | TWEIDEM1 | APPROVAL SHELF | Completed |
01/19/2018 | TWEIDEM1 | OUT TO CUSTOMER | Completed |
01/19/2018 | TWEIDEM1 | REJECT SHELF | Completed |