Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Permit Number - T17CM08392
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/09/2017 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | P&DS TRANSMITTAL FROM: Steve Shields, Principle Planner PROJECT: T17CM08392 TRANSMITTAL: November 9, 2017 COMMENTS: the following comments are relative to an application for Neighborhood Preservation Zone Review (UDC 5.10.3). This site is located in the NR-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). |
| 11/09/2017 | AHINES2 | ENGINEERING | REVIEW | Passed | |
| 11/09/2017 | AHINES2 | NPPO | REVIEW | Passed | |
| 11/09/2017 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active |