Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T17CM07967
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/26/2018 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T17CM07967 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide two sets of updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. FOUNDATION PLANS: 1. Indicate the direction of slope for the garage slab, R309.1. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. PLUMBING PLANS: 1. Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). Show a 1-1/4" pipe between the meter and first branch tee. MECHANICAL PLANS: 1. Show impact protection for the water heater located in the garage, M1307.3.1. ELECTRICAL PLANS: 1. Update the panel schedule showing each circuit description, E3404.12 & E3706.2. OUTDOOR LIGHTING CODE 1. Show the proposed fixtures as full cut-off FCO style. Full cut-off fixtures are non-adjustable with no light above the horizontal plane (fixtures are completely closed above and to the lowest point of the lamp). If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 05/02/2018 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera PDSD Zoning Review Section PROJECT: T17CM07967 Family Dwelling additions (2nd Review) 5324 E. Burns Street TRANSMITTAL DATE: May 2, 2018 DUE DATE: May 3, 2017 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: Zoning has done a second review of the permit application for the proposed additions but cannot approve the plans at this time. 2. COMMENT: In the initial review done by zoning, deficiencies in the building setbacks were identified. At that time the Zoning reviewer generated review comments that were related to the non-compliant setbacks and referred the applicant to the Zoning administration section to process a Design Development Option. As of this 2nd zoning review the DDO has not been approved and will not be completed until mid to late May. Until the DDO is approved zoning cannot approve the building permit application. 3. COMMENT: Include a lot coverage calculation under the area calculations text block. 4. COMMENT: When the DDO process is completed and approved the plans will be stamped by the Lead Planner that processes the DDO applications. The DDO stamped and approved drawings will have to be included in the permit application packet at time of the next submittal. 5. COMMENT: Zoning will review the building permit application and review the DDO documents and the building plans and site plan to assure that no changes have been made and that the plans are consistent with the DDO approved plans,. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/15/2018 | QJONES1 | APPROVAL SHELF | Completed |
| 05/15/2018 | QJONES1 | OUT TO CUSTOMER | Completed |
| 05/15/2018 | QJONES1 | REJECT SHELF | Completed |