Permit Review Detail
Review Status: Completed
Review Details: WALK THRU - RES
Permit Number - T17CM07943
Review Name: WALK THRU - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2017 | TOM WEIDEMAN | ENGINEERING | REVIEW | Passed | |
| 11/01/2017 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | T17CM07943 PLAN REVIEW COMMENTS Plan review for the above referenced structure is completed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code, 2012 International Fire Code, 2011 National Electrical Code and Arizona Revised Statutes. All features were checked to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Make all corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. GENERAL NOTES: 1. Provide an electrical engineer's seal for verifying code compliance for the power wall and associated equipment and materials. DIAGRAMS / CALCULATIONS 1. The feeder conductors placed between the two source breakers require a rating not less than 120% of the sum of those breakers, NEC 690.64 & 705.12 (D). The FEEDER CONDUCTOR (0) requires a rating for receiving electrical power from two sources 200A and 60A. Show a feeder conductor with ratings not less than 217A for the source breakers as shown. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |