Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T17CM07814
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2017 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 11/13/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheets 1 through 3; Contech Engineered Solutions LLC Bridge Drawings: Please provide two sets of the sealed/signed/dated structural calculations for the bridge design. 2. General; Contech Engineered Solutions LLC: The Arizona State Board of Technical Registration requires the design professional sign the seal on all documents, and include the date the document was sealed. In addition, a notation shall be placed beneath the seal that provides the day, month, and year of the expiration of the current registration. Please provide all as required. 3. Sheets 1 through 2; Contech Engineered Solutions LLC Abutment Drawings: Please provide two sets of the sealed/signed/dated structural calculations for the abutment design. 4. Sheet S1.1; Structural Notes: It is noted that a geotechnical report was used for the foundation design. Please provide one copy of that report for review. 5. Sheets S1.1 through S1.3; Oliden Engineering Radius Arch Drawings: Please provide two sets of the sealed/signed/dated structural calculations for the arch design. 6. Sheets 1 through 4; Contech Engineered Solutions LLC Radius Arch Drawings: Please provide a seal, signature, and dates on all drawings. 7. Drawings Number 3 and Number 6; Retaining Wall Drawings: The City of Tucson requires all lettering (upper and lower case) to be a minimum of 3/32" in height. Please revise as required. 8. General; All: Please provide a special inspection certificate (available on the City of Tucson website) for all categories of special inspections required, and the name of each special inspector for the specific categories. 9. General: Please provide written responses to all review comments. |
| 11/17/2017 | STEVE SHIELDS | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/29/2017 | KROBLES1 | OUT TO CUSTOMER | Completed |