Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T17CM07618
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/28/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Completed | |
| 11/29/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide a 3" floor drain, not a 2" floor drain. [Initial comment: Provide a 3" floor drain to drain the entire floor area of the laundry room. Reference; Section 412.4, IPC 2012.] |
| 11/29/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Submit a COMcheck Envelope Compliance Certificate for the building alterations. Show the U-values, SHGF, and R-values of all of the components used for COMcheck on the drawings (doors, windows, walls, and roof). [Initial comment: Demonstrate energy code compliance for the alterations to the building envelope based on the current code (e.g. new fenestration and new exterior walls). Reference: Sections C101.4.3, C101.5, C103.2, C303, and C401.2.1, International Energy Conservation Code 2012.] |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/08/2017 | QJONES1 | APPROVAL SHELF | Completed |
| 12/08/2017 | QJONES1 | OUT TO CUSTOMER | Completed |
| 12/08/2017 | QJONES1 | REJECT SHELF | Completed |