Permit Number: T17CM07448
Parcel: 12410504A

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T17CM07448
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/29/2017 KELLY LEE ZONING REVIEW Approved
09/29/2017 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
09/29/2017 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
09/29/2017 KLEE1 ENGINEERING REVIEW Passed
09/29/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet T1.0 (Scope); Sheet T2.0 (Exit Diagram): The Scope indicates no change in use or square footage, while the exit diagram indicates 'expands into existing suite #103. Please clarify.
2. Sheet T2.0; Occupant Loads: The storage occupancy type indicates 500 SF/occupant for the occupant load. Per the IBC Table 1004.1.2, use 300 SF/occupant (accessory storage areas). Please revise the occupant load.
3. Sheet T2.0; Code Review: The fire resistance rating requirements indicate interior bearing walls are provided with a two hour rating. Please revise (no interior bearing walls).
4. Sheet A2.0; Detail 4: Please indicate the brace size, and include connector size/quantity at the top of the partition and to the structure above.
5. General: Please provide written responses to all review comments.
09/29/2017 ROBERT SHERRY WATER REVIEW Completed
09/29/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
09/29/2017 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
10/02/2017 MARTIN BROWN FIRE REVIEW Approved