Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T17CM07443
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/11/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Of the seven entries in the "mandatory measures", only one, entry g, applies to this activity. [Second comment: Comment not addressed.] [Initial comment: Edit the plumbing notes and "mandatory measures" to contain only those items that apply to this activity. Reference: Section 107.2.1, IBC 2012.] 2. The specified water heater (Bosch Tronic ES2.5) is a mini-tank water and will require the installation of an expansion tank and a T&P relief. Reference: Section 504 and 607, IPC 2012. [Second comment: If the hot water piping is running above the T-bar ceiling (10' AFF), won't the vertical rise from the water heater and the drop to the hand sink increase the developed pipe length to over 50-feet?] [Initial comment: The maximum developed length of the hot water supply piping appears to be greater than fifty feet; provide a method for maintaining the temperature of the hot water supply system. Reference: Section 607.2, IPC 2012.] |