Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T17CM06272
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/15/2017 | ANDREW CONNOR | ZONING | REVIEW | Approved | |
| 08/15/2017 | ACONNOR1 | ENGINEERING | REVIEW | Passed | |
| 08/16/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 08/16/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 08/16/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet G1: Please revise the spelling of Tucson on this sheet (several locations). 2. Sheet A1 (Floor Plan); Sheet G2 (Door Schedule): Door 109 in the southeast corner of the plan is not listed in the door schedule. Please revise. 3. Sheet A1; Keyed Notes: Note 1 indicates a door chime is 13'-0" aff. Please verify the chime location. 4. Sheet A1; Floor Plan: No drinking fountain was located on the plan. Detail 13/A4.3 provides a detail of a high/low drinking fountain. Please indicate a location on the plan. 5. Sheet A2; Fixture Plan: The City of Tucson requires fixture information on the drawings as follows: a) If the fixture is six feet or less in height, locate and identify the fixture on a plan; b) If the fixture is greater than six feet and equal to or less than twelve feet in height, locate and identify the fixture on a plan, and provide a detail on the drawings for the fixture connection to the floor; c) If the fixture is greater than twelve feet in height, locate and identify the fixture on a plan, provide stamped structural calculations for the fixture, and provide a detail on the drawings for the fixture bracing and connection to the floor. Please verify. 6. Sheet A4.4; Toilet Room Plan: In the men's restroom, the elevation indicators 5 and 6 are reversed. Please verify. 7. Sheet A4.4; Fitting Room Plan: Please locate this plan on the floor plan on Sheet A1. 8. General: Please provide written responses to all review comments. |
| 08/16/2017 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 08/16/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 08/16/2017 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/16/2017 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 09/21/2017 | KROBLES1 | WWM | REVIEW | Passed |