Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T17CM06165
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/10/2017 | ANDREW CONNOR | ZONING | REVIEW | Approved | |
| 08/10/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 08/10/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please indicate branch circuit and panel designation on the floorplan for lighting and water heater. Provide for water heater disconnecting means. Ref: 2011 NEC 408, 2012 IBC 107.2.1 |
| 08/10/2017 | ACONNOR1 | ENGINEERING | REVIEW | Passed | |
| 08/10/2017 | TPROBAS1 | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Please include ANSI A117.1-2009 to the code reference. 2. Provide ADA details which corelate with ANSI A117.1-2009 figures 604.3, 604.5.1 & 604.5.2. 3. As proposed, the configuration of the restrooms do not meet ADA requirements. Please revise to correlate with the requirements of ANSI A117.1-2009 Chapter 6. 4. Provide wall details for the new walls to be constructed. Include in the detail: framing type, size and spacing, wall finish material, anchorage, bracing to structure above including type of bracing material, spacing, type and number of fasteners to be used. |
| 08/10/2017 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Reduced pressure backflow prevention assemblies are required at the water meter for multi-use commercial buildings. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, http://www.tucsonaz.gov/files/water/docs/backflow-ordinance.pdf |
| 08/10/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide information to show how the proposed water heater is to be supported from the building structure. Reference: Section 301.2, IPC 2012. |
| 08/10/2017 | TPROBAS1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 08/11/2017 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 08/30/2017 | KROBLES1 | WWM | REVIEW | Completed | P17WX01942 |