Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T17CM06144
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide automatic faucets for the new lavatories, dispensing a maximum of 0.25 gallons per metering cycle. Verify that the automatic faucets will operate for at least 10-seconds for accessibility. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. Provide tempered water for the public restroom lavatories using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012. 3. Show the location of the required drinking fountains. Reference: Sections 1109.5 and 2902.1, IBC 2012. |
| 08/24/2017 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/24/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 09/06/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet G000 Sheet Index: Sheet CD000 Existing Conditions is denoted on the Sheet Index, Existing Conditions is on Sheet CD00 of submitted drawings. Coordinate. 2. Sheet G000 Code Analysis: Please include ANSI A117.1-2009 as an applicable code. 3. Sheet G001: Update notations and details as necessary to reference ANSI A117.1-2009. 4. Sheet G010 First Floor Life Safety Plan: The Required and Provided Exit width notations are too small. The City of Tucson requires all lettering, upper and lower case, to be a minimum of 3/32" in height. Please enlarge text. 5. Sheet A101 detail 3A, Keynote A06: Include on the drawings a wall detail for the support wall identified in Keynote 06. Include framing member type, size and spacing, anchoring, bracing and wall covering material. 6. Sheet A101: Include on the drawings the required clear floor space and maneuvering clearances at accessible building elements. Reference ANSI A117.1-2009 Chapter 3 & 4. 7. Sheet A101 Detail 4C, Keynote A22: Include on the drawings a wall detail for the new wall identified in Keynote 22. See comment 5 for more information. 8. Sheet A101: Revise Details 4C, 5A, 5B, 5C, 6A & 6B to correlate with ANSI A117.1-2009 Figures 604.3, 604.4, 604.5.1 & 604.5.2. Also, coordinate mounting heights on Sheet G001. 9. Sheet A101: Include on the drawings the Specifications and Mounting Locations of signage for Accessible Restrooms. Reference ANSI A117.1-2009 Section 703 10. General: Provide written responses to all comments. |
| 09/20/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Passed |