| 09/06/2017 | PIMA COUNTY | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T17CM05981 - PLAN REVIEW COMMENTS Reviewer: John Farmer, September 5, 2017 BUILDING – Porch Provide details of the porch roof construction. Show ledger size and detail connection to the structure. Identify rafter connection to the ledger and the beam. Identify rafter and beam sizes. Indicate roof sheathing and finish surface type. Show the slope of the porch roof. BUILDING- Plumbing Gas line calculations are required. Provide the total developed length and the total BTUs of all appliances serviced. BUILDING- Electrical Provide the wire size and type between the main panel and the sub-panel. Provide smoke alarms in and out of each sleeping area. Provide carbon monoxide alarms in the immediate vicinity of all bedrooms. |