Permit Number: T17CM05625
Parcel: 135070660

Address:
7828 E 34TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T17CM05625
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2018 DRIVERA1 ENGINEERING REVIEW Needs Review
01/04/2018 DRIVERA1 BUILDING-RESIDENTIAL REVIEW Needs Review
08/24/2017 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

FROM: Steve Shields,
Lead Planner


PROJECT:
T17CM05625
7828 E. 34th Street
Convert carport to garage and expand


TRANSMITTAL: August 24, 2017

COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 9'-9" the required perimeter yard setback from the proposed garage addition to the east property line is 6'-6", proposed is 6'-0".

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height of 7'-9" the required street perimeter yard is 20'-0", proposed is 12'-0".

The minimum setback to the back of a sidewalk for a garage is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a garage is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b.). Proposed distance to the sidewalk is 14'-0", proposed distance to the property line is 12'-0".
08/24/2017 SSHIELD1 NPPO REVIEW Passed