Permit Review Detail
Review Status: Completed
Review Details: WALK THRU - COMM
Permit Number - T17CM05431
Review Name: WALK THRU - COMM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/17/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Please provide structural calculations and drawings as required for new unit on existing roof. Verify existing roof structure can support the new load. Add framing as required on a full size drawing, including sections/details, and plans. |
| 07/17/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Provide a mechanical design for the installation of the new AC unit. Include heating/cooling load calculations and demonstrate compliance with Section C403, IECC 2012. |
| 07/17/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 07/17/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed |