Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T17CM05147
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/31/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet PV1.0 (System Description); Sheet PV1.1 (Array Plans P1 and P2): Sheet PV1.0 indicates array P1 has an area of 5590 SF and array P2 has an area of 3633 SF for a total of 9223 SF. Sheet PV1.1 indicates array P1 is 167'-9" long x 34'-0" wide (5704 SF), and array P2 is 181'-9" long x 20'-5" wide (3712 SF) for a total of 9416 SF. Please coordinate. 2. Structural Calculations (P1); Beam Design: The three beam designs indicated in the calculations are for a 24' span with an 8' cantilever, a 26.25' span with an 8.75' cantilever, and another 26.25' span with an 8.75' cantilever. Please revise. 3. Structural Calculations (P1); Beam/Column Design: The length of beam M1 on SK-1 indicates 32.416', and the length of the column M2 indicates 11.297'. Please verify the member sizes using revised lengths. 4. Structural Calculations (P2); Beam/Column Design: See Comment 3 for member sizes. Please verify. 5. General: Please provide written responses to all review comments. |
| 07/31/2017 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/03/2017 | KROBLES1 | OUT TO CUSTOMER | Completed |