Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/14/2017 | ANDREW CONNOR | ZONING | REVIEW | Approved | |
06/14/2017 | ACONNOR1 | ENGINEERING | REVIEW | Passed | |
06/22/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
06/22/2017 | TPROBAS1 | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
06/22/2017 | TPROBAS1 | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Occupant load shall be at a rate of 1/15 for assembly, unconcentrated. 2. Sheet A2.01 references detail 13/A4.03. There is no sheet A4.03. 3. Provide an attachment detail for the firred walls to masonry. 4. Provide an elevation drawing of the counters which complies with ADA for at least one space. 5. Structural to evaluate the existing roof for the new Rooftop unit and provide detail. 6. Need special inspection certificate for masonry and field welding (optional lintel). |
06/22/2017 | MARTIN BROWN | FIRE | REVIEW | Reqs Change | Please review section 1008.1.10 of the 2012 International Fire Code for panic hardware. Revise plans accordingly. It appears door width calculations are based on a sprinklered building. Please review. |
06/22/2017 | TPROBAS1 | PLUMBING-COMMERCIAL | REVIEW | Completed | |
06/22/2017 | TPROBAS1 | WATER | REVIEW | Passed | |
06/27/2017 | KROBLES1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
06/27/2017 | GERRY KOZIOL | WWM | REVIEW | Completed |