Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T17CM04539
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 06/12/2017 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 06/12/2017 | ACONNOR1 | ENGINEERING | REVIEW | Passed | |
| 06/12/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Verify that the specified lavatory faucets will be set to dispense a maximum of 0.25 gallons per metering cycle. The dispensing cycle shall last for at least 10-seconds for accessibility. Reference: Section 416.6, IPC 2012, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 2. Provide tempered water for the public restroom lavatories using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2012. |
| 06/12/2017 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 06/12/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 06/12/2017 | ANDREW CONNOR | ZONING | REVIEW | Approved | |
| 06/13/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please provide full compliance with the 2012 IECC for the lighting. |
| 06/13/2017 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 06/14/2017 | GERRY KOZIOL | WWM | REVIEW | Completed |