Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T17CM04454
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/07/2017 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 06/07/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 06/30/2017 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Principle Planner PROJECT: Alorica T17CM04454 Building Plan (1st Review) TRANSMITTAL DATE: June 30, 2017 1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. As vehicle parking is being removed for placement of the generator provide an updated vehicle parking space calculation. 3. Sheet E1.1 shows the generator in a different location than sheet S1.1, clarify which is correct. 4. Sheet E1.1 shows the generator directly adjacent to the vehicle parking space to the south. Per UDC Article 7.4.6.D.2.b Minimum Width Requirement When Adjacent to Barrie A motor vehicle off-street parking space must have a minimum width of ten feet when the side(s) of the parking space abuts a vertical barrier over six inches in height, other than a vertical support for a carport. Demonstrate that the vehicle parking space meets the above requirements. 5. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 07/11/2017 | TPROBAS1 | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet S1.1: Sheet is labeled Not For Construction. Please revise. 2. Sheet S1.1: Registrant seal is is covered with text and is not legible. Registrant seal must be legible. 3. Sheet S1.1: HIT RE 500 Adhesive Anchor Report #2322 is no longer valid. Please provide valid report. 4. HIT 150 MAX SD Report #3013 is no longer valid. Please provide a valid report. 5. General: Please provide a special inspection certificate for all required Special Inspections. 6. Provide structural calculations for foundation. 7. General: Provide written responses for all comments. |
| 08/04/2017 | MARTIN BROWN | FIRE | REVIEW | Approved | Please provide mnfgf's cut sheets for generator. Clarify if diesel is self contyained within the unit, or a separate containment tank for the fuel is required. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/04/2017 | KROBLES1 | OUT TO CUSTOMER | Completed |