Permit Number: T17CM04364
Parcel: 11505087J

Address:
2332 N ORACLE RD

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T17CM04364
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/06/2017 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: T17CM04357 and T17CM04364
(Retail Use - Convenience Store with Fuel Pumps)
Building Plan Review (1st Review)
333 W. Grant Road

TRANSMITTAL DATE: June 6, 2017

DUE DATE: June 28, 2017

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. COMMENT: Zoning has reviewed the building plans for the C-Store and Fuel Canopy for compliance with the approved development package. While the building footprint for the C-Store and Fuel Canopy are consistent with the building footprints on the approved development package as it relates to the zoning review purview such as but not limited to building footprint (Square footage), building location, Building height, and use, zoning cannot approve the plans at this time.

As of this zoning review of the building plans, the plan review by the PDSD commercial plans review agencies had been completed. Zoning cannot approve the building plans until all commercial review agencies have approved and signed the building plans.

2. COMMENT: The copy of the DP included in the building package is not the approved and signed copy. Remove the unapproved copy of the DP and replace it with the approved and signed copy or label the plans as "Reference only see approved and signed DP17-0046".

3. COMMENT: Zoning will review the building plans on the next submittal to assure that any revisions made to the building plans do not affect zoning requirements and that the above comments have been addressed.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov
06/07/2017 MARTIN BROWN FIRE REVIEW Approved
06/14/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/26/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Completed
06/26/2017 TPROBAS1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
06/29/2017 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
06/30/2017 LOREN MAKUS ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/07/2017 ARUIZ1 OUT TO CUSTOMER Completed