Permit Review Detail
Review Status: Active
Review Details: RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU
Permit Number - T17CM03731
Review Name: RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/11/2017 | ANDREW CONNOR | ZONING | REVIEW | Reqs Change | COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The applicant is proposing a 19' 4" tall attached garage. The proposed side-yard setback is 4' 5" to the Northeast. The required setback would be 12' 10" from interior property line. |
| 05/11/2017 | ANY | ENGINEERING | REVIEW | Active | |
| 05/11/2017 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 05/11/2017 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active |