Permit Number: T17CM03513
Parcel: 140420740

Address:
7250 S TUCSON BL

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T17CM03513
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2017 ANDREW CONNOR ZONING REVIEW Passed
05/04/2017 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
05/04/2017 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
05/04/2017 PAUL BAUGHMAN ENGINEERING REVIEW Passed
05/04/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Needs Review
05/04/2017 ROBERT SHERRY WATER REVIEW Completed
05/04/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Clarify the size of the fixture drain for the mop sink; it is 3" on the riser diagram and 2" on the plumbing floor plan. Reference: Section 107.2.1, IBC 2012.
2. The 3" horizontal drain starting at the junction of the fixture drains for the drop sink and the floor sink has no 3" cleanout. Provide cleanouts sized for the nominal size of pipes that they serve up to 4-inches. Reference: Section 708.7, IPC 2012.
3. Provide separate indirect waste pipes for each compartment of the 3-compartment sink to protect against cross-contamination or fouling. Reference: Sections 801.2 and 802.1.8, IPC 2012.
05/04/2017 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
05/05/2017 JVINCEN1 FIRE REVIEW Approved
05/19/2017 ARUIZ1 WWM REVIEW Needs Review