Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Active
Review Details: COMMERCIAL - TI
Permit Number - T17CM02437
Review Name: COMMERCIAL - TI
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/29/2017 | ANDREW CONNOR | ZONING | REVIEW | Approved | |
| 03/29/2017 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Needs Review | |
| 03/29/2017 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 03/29/2017 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
| 03/29/2017 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A1.0; FLOOR PLAN: FOR A B OCCUPANCY WITH MORE THAN 15 OCCUPANTS, TWO RESTROOMS ARE REQUIRED PER THE IBC TABLE 2902.1. PLEASE REVISE. 2. SHEET A2.0; ENLARGED PLAN 5: PLEASE INCLUDE ELEVATIONS FOR THE GRAB BAR LOCATIONS PER THE ICC/ANSI FIGURES 604.5.1 AND 604.5.2 ON THIS SHEET (NOTED ON THIS PLAN). 3. SHEET A3.0; DETAIL 1: PLEASE INCLUDE THE BRACE SIZE, OR REFERENCE METAL WALL STUD. 4. SHEET A3.0; DETAIL 2: PLEASE INDICATE THE BOLT SIZE THAT CONNECTS THE HOT WATER HEATER FRAME TO THE WALL ('ANCHOR TO WALL IN APPROVED MANNER' IS NOT ACCEPTABLE. 5. SHEET A3.0; DETAIL 2: PLEASE INDICATE THERE ARE TWO OF THE ANGLE FRAMES AT THE HOT WATER HEATER. 6. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 03/29/2017 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 03/29/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 03/29/2017 | ANY | FIRE | REVIEW | Active | |
| 03/29/2017 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 03/29/2017 | ANY | WWM | REVIEW | Active |