Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T17CM01801
Parcel: 13803031T

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - COMM

Permit Number - T17CM01801
Review Name: PLANS OK TO SUBMIT - COMM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/07/2017 ANDREW CONNOR ZONING REVIEW Passed
03/07/2017 ENEWCOM1 ADA REVIEW Passed
03/07/2017 ENEWCOM1 FIRE REVIEW Needs Review
03/07/2017 ARUIZ1 WWM REVIEW Completed
03/07/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Needs Review
03/07/2017 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/07/2017 PAUL BAUGHMAN ENGINEERING REVIEW Approved March 7, 2017
FLOODPLAIN USE PERMIT NO.: T17OT00245
ADDRESS: 850 W Valencia Tucson, Arizona 85706
OWNER: Southgate Academy Inc
850 W Valencia Road Tucson, Arizona 85706

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the City of Tucson Flood Hazard Area delineation of the Valencia Wash, specifically described as:

A portion of Parcel 138-03-031T, King Wheeler Center SELY PTN EXC ROAD BLK 1
For the purpose of remodeling an existing non-conforming structure and restriping the parking lot.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 11 conditions:

1) All improvements proposed under this permit will be cumulative, over a ten(10) year period, in percentage, to include this project.
2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value.
3) A cost estimate was provided showing that the improvements are less than 50 % (estimate was 5.9%) of the Assessed Value ($5,483,080), as shown on the Pima County Assessors Website. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and if piecemeal permits for this construction are applied for the cost estimate will be added to it.
4) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
5) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times.
6) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval.
7) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance.
8) The associated improvements are with permit activity number T17CM01801.
9) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
10) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.
11) This permit is specific to the improvements for 850 W Valencia as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Jeff Sharifi
ADDRESS: 1225 W. Miracle Mile Tucson, Arizona 85705
PHONE: 520-907-5231
CONTRACTOR: 4 Diamond Buildlers, LLC
ADDRESS: 1225 W Miracle Mile Tucson, Arizona 85705
PHONE: 520-907-5231

(EXPIRATION DATE) Month: 03 Day: 07 Year: 2018

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.