Permit Number: T17CM01431
Parcel: 12801005H

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T17CM01431
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Previous comment 1; Sheet G-001; Site Information/Occupancy: This occupancy classification should be an A-2 (restaurant) per the IBC Section 303. The drawing indicates 'retail sales and services' (M occupancy), which is incorrect. Please revise the drawing. In addition, the occupancy load for this project should be calculated using the seating summary shown on Sheet G-005 (indoor and outdoor seating), plus the indoor incidental areas as shown on the plan. The total occupant load for this project appears to be 1 (workshop) + 1 (backbar) + 15 (as indicated for indoor seating on the north wall) + 8 (as indicated for outdoor seating) + 3 (sales) + 6 (as indicated for indoor seating on the south wall) + 2 (sales) = 36. The restroom area, vestibule area, and path of travel area are not included. Please verify these numbers, and revise Sheets G-001 and G-005 to reflect the occupant loads. With this occupant load, the IBC Section 303.1.1 indicates the assembly use can be classified as a Group B occupancy. Please add verbiage on Sheet G-001 to reflect this.
2. Previous comment 2; Sheet G-005; Total Square Footage: Please provide the total gross square footage for the interior of the building, the total gross square footage for the exterior seating space, and the combined gross square footage for these areas on the sheet.
3. General: Please provide written responses to all review comments.
04/20/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The specified Wilkins 700XL dual check valve is listed to ASSE 1024; a dual check valve with an intermediate atmospheric vent (ASSE 1022) is required for the backflow protection of beverage dispensers. [Initial comment: Water supply connections to beverage dispensers shall be protected with backflow preventers conforming to ASSE 1022. Reference: Section 608.16.1, IPC 2012.]
04/20/2017 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change The Turbochef oven (design ID 12407) is a cooking appliance that produces heat but does not necessarily require the installation of a Type II hood. Provide general room exhaust per Section 507.2.2, IMC 2012 or install a Type II hood. [Initial comment: Provide general room exhaust for any cooking appliance that does not require the installation of a Type II hood. The minimum exhaust rate shall be 0.70 CFM per square foot, using a minimum area of 100 square feet for each individual appliance. Reference: Section 507.2.2, IMC 2012.]
04/27/2017 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
05/04/2017 GERRY KOZIOL WWM REVIEW Completed P17WX01144