Permit Number: T17CM00791
Parcel: 130055610

Address:
2409 S MCFEE SV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T17CM00791
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/31/2017 PAUL BAUGHMAN ENGINEERING REVIEW Approved
01/31/2017 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
05/04/2017 ANDREW CONNOR ZONING REVIEW Reqs Change COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The applicant is proposing an 11' 6" tall attached garage. The proposed side-yard setback is 6' 6" to the Southwest. The required setback would be 7' 6".
05/04/2017 ANDREW CONNOR NPPO REVIEW Passed